Are you working with electric motors or there is the need to specify motors and you need to know what standard applies to what area of electric motors? The table below will be of great help as it itemizes the basic standards that define all areas of electric motor design, construction and installation:
International Standard IEC
|
Harmonized European Standard
|
Description
|
| IEC 60034-1 +A1 and A2 | EN 60034-1+A1, A2 and All | Rotating electric motors. Part 1: Rating and design |
| IEC 60034-2+A1, A2 and IEC 60034-2A | EN 60034-2 + A1 and A2 | Rotating electric motors. Part 2: Measuring methods to determine the loss and the efficiency of electric motors (except machines for traction vehicles) |
| IEC 60034-5 | EN 60034-5 | Rotating electric motors. Part 5: Enclosure class for rotating electric motors. |
| IEC 60034-6 | EN 60034-6 | Rotating electric motors. Part 6: Cooling (IC code) |
| IEC 60034-7+A1 | EN 60034-7+A1 | Rotating electric motors. Part 7: Classification of types of construction and mounting (IM code) |
| IEC 60034-8 | EN 60034-8 | Rotating electric motors. Part 8: Terminal marking and direction of rotation |
| IEC 60034-9 | EN 60034-9 | Rotating electric motors. Part 9: Noise limits |
| IEC 60034-11 | - | Thermal protection |
| IEC 60034-12 | EN 60034-12 | Rotating electric motors. Part 12: Start capacity of three-phase induction motors. |
| IEC 60034-14 | EN 60034-14 | Rotating electric motors. Part 14: Mechanic vibration for machines with drive shaft heights of 56mm or more. Measuring, estimate and vibration limits |
| IEC 60038 | - | IEC Standard Voltages. |
| IEC 60072-1 | EN 50347 | Dimensions and output power for rotating electric motors. Part 1: Frame size 56 to 400 and flange size 55 to 1080. |
| IEC 62114 | - | Electrical insulation systems |
| - | EN 50102 | Degrees of protection for enclosures for electrical equipment against external mechanic strokes. (IK-code) |
| IEC 60072-1 | EN 50347 | Three-phase induction motors for standard use with standard dimensions and output power. Frame size 56 to 315 and flange size 65 to 740. |
Other Standards
|
||
| DIN 51825 | Lubricant; lubricating grease k; classification and requirement (1990-08) | |
| DIN 44082 | Thermistors; PTC sensors; thermal protection of machines; climate categorization HFF (1985 -06) | |
| ISO 2409 | EN ISO 2409 | Paints and enamels. Grid cut value. |
| - | EN ISO 3743-2 | Definition of sound power level. Minor removable sources of noise. Engineering method. Part 2: Rooms with sound control |
| - | EN ISO 4871 | Declaration and verification of noise from machines and equipment. |
| - | EN ISO 11203 | Noise from machines and equipment. Measurement of sound pressure by the operator's ear (noise emission). Calculation on the basis of sound power level. |